Magnetic Resonance
MR-only simulation  Unleash the real power of MR simulation
This product is no longer available

MR-only simulation

Unleash the real power of MR simulation

This product is no longer available

Find similar products

Innovative MR-only simulation pelvis lets you plan radiation therapy for male and female pelvic cancer patients with soft-tissue tumors using MRI as a single-modality solution. Within just one MR exam, MR-only simulation provides excellent soft-tissue contrast for target and OAR delineation, and CT-like density information for dose calculations. This not only extends the benefits of MRI’s outstanding soft-tissue contrast to radiotherapy planning, but it also eliminates arduous, error-prone CT-MRI registration from the process, reducing uncertainties and complexity.

Specifications

MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
Compatibility with MR-based auto-contouring
  • No
Density maps
  • Continuous Hounsfield Units
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
Compatibility with MR-based auto-contouring
  • Yes, for prostate and prostate OARs
Density maps
  • Discrete, five different classifications: water, fat, spongy bone, cortical bone, and air
MR-only simulation
MR-only simulation
Compatibility
  • Ingenia MR-RT 1.5T and 3.0T
Imaging protocol
  • Dedicated ExamCard provides sequences for:
  • 3D MRCAT source information (mDIXON)
  • Anatomical information for delineation (T2W TSE)
MRCAT generation
  • Running parallel to image acquisition on the MR console, embedded post-processing generates MRCAT images using:
  • Automated segmentation and tissue classification
  • Automated assignment of CT-based density values
Export to treatment planning systems
  • MRCAT images are DICOM conform (CT) for direct export to treatment planning systems
MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
See all specifications
MR-only simulation pelvis
MR-only simulation pelvis
Anatomies
  • Male and female pelvis, which includes prostate, bladder, rectum, anus and cervix
Compatibility RTdrive
  • No
Compatibility with MR-based auto-contouring
  • No
Density maps
  • Continuous Hounsfield Units
MR-only simulation prostate
MR-only simulation prostate
Anatomies
  • Prostate
Compatibility RTdrive
  • Yes
Compatibility with MR-based auto-contouring
  • Yes, for prostate and prostate OARs
Density maps
  • Discrete, five different classifications: water, fat, spongy bone, cortical bone, and air
MR-only simulation
MR-only simulation
Compatibility
  • Ingenia MR-RT 1.5T and 3.0T
Imaging protocol
  • Dedicated ExamCard provides sequences for:
  • 3D MRCAT source information (mDIXON)
  • Anatomical information for delineation (T2W TSE)
MRCAT generation
  • Running parallel to image acquisition on the MR console, embedded post-processing generates MRCAT images using:
  • Automated segmentation and tissue classification
  • Automated assignment of CT-based density values
Export to treatment planning systems
  • MRCAT images are DICOM conform (CT) for direct export to treatment planning systems
  • 1. Accuracy means: MRCAT provides around 1 mm total geometric accuracy of image data in less than 20 cm Diameter Spherical Volume (DSV). MRCAT provides below 2 mm total geometric accuracy of image data in more than 40 cm Diameter Spherical Volume (DSV)*. * Limited to 32 cm in z-direction in more than 95% of the points within the volume
  • 2. Equivalent means: the simulated dose based on MRCAT images does not differ in 95% of the pelvic cancer patients (Gamma analysis criterion 3%/3mm realized in 99% of voxels within the PTV or exceeding 75% of the maximum dose) when compared with CT-based plan for EBRT.
  • 3. Tested in a non-clinical environment with single Pinnacle user and a 5-beam IMRT plan. Excluding time for optional manual adjustments.

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.

Ön belépni kíván a magyar Philips Healthcare weboldalára.
Please select the checkbox

Ez a weboldal kizárólag olyan személyek számára készült, akik mint szakemberek használják az orvostechnikai eszközöket, ideértve az orvosi szakmát gyakorló személyeket, az egészségügyi intézmények képviseletében eljáró magánszemélyeket vagy az orvostechnikai eszközöket szakmai célból vásárlókat.

Ön olyan személy, aki megfelel a fenti kritériumoknak?